Important to read in addition to this page is the
Do's and Don'ts of Oven
Venting
International Customers:
Click Here
This information is provided to assist in
safe and functional installation of Wood Stone MS series ovens. Above
all, the oven must be installed in accordance with all relevant local
and national codes, and in a manner acceptable to the authority having
jurisdiction.
The following are the manufacturer’s
recommendations for venting Wood Stone Mountain Series (MS) ovens. It is
never appropriate to use "B vent" in any part of an exhaust system
connected to a Wood Stone oven. All ducting material must be
manufactured to the specifications of a grease duct. Due to the
possibility of sparks entering the duct, exhaust systems serving
SOLID FUEL equipment SHOULD NOT be combined with exhaust systems serving
other (non-solid fuel) cooking equipment. Submit you venting plans to
your local authorities before proceeding with your installation, as
there may be additional requirements in your area.
There are three options:
1.
Direct connection.
A Listed building heating appliance chimney, also listed as a
grease duct as described in NFPA 96, connected directly to the oven flue
collar and provided with a power ventilator listed for restaurant
appliance exhaust. The power ventilator should be rated for a minimum of
300 degrees F (450 degrees F for W, W-IR, RFG-IR-W and RFG-W solid fuel
models). Wood Stone does not recommend the use of an in-line fan. A
field-built duct, constructed and installed to the specifications of a
grease duct, as detailed in NFPA 96 or the International Mechanical
Code, may also be used.
A static pressure of -0.1
inches water column (-0.14 for W, W-IR, RFG-W, and RFG-IR-W solid fuel
models) is necessary at the oven flue collar to ensure that gas
temperatures do not exceed 300 degrees Fahrenheit (450 degrees F for
models that burn solid fuel) at the fan inlet. The CFM required to
attain this static pressure will depend on the configuration of your
particular installation but will probably be between 500 and 750 CFM.
Wood Stone provides a port in the flue collar of the oven for insertion
of a Magnehelic gauge so the installer can monitor the draft to ensure
proper operation of the venting system. Note: Double door ovens
(DD), have two flue collars, both must be connected and a static
pressure of - 0.1 inches(-0.14 inches for models that burn solid fuel)
must be maintained at each collar.
When using a direct connection as
described above, order the optional flue adapter from
Wood Stone. The duct must be attached to the optional flue adapter with
a full perimeter weld or a Listed Connector.
The venting system must be installed in
accordance with manufacturer's instructions and in accordance with all
local codes. All field built components should be built to the
applicable codes and standards and are subject to the approval of the
authority having jurisdiction.
|
Oven
Model Series |
Flue Collar |
| Mt. Chuckanut |
WS-MS-4 |
8 inch
O.D.* |
| Mt. Adams |
WS-MS-5 |
10 inch I.D. |
| Mt. Baker |
WS-MS-6 |
10 inch I.D. |
| Mt. Rainier |
WS-MS-7 |
10 inch I.D. |
|
*Note:
MS-4 ovens come standard with a round 8"
O.D. collar and do not require the optional flue adapter for a
direct connection.
2. A listed Type 1 Exhaust Hood or one
that is constructed and installed in accordance with NFPA 96 and all
relevant local and national codes. Solid-fuel burning equipment must
be vented in accordance with NFPA 96.
Wood Stone offers
eyebrow-type hoods designed specifically for Wood Stone ovens. For
specifications see
Hoods & Fans for Wood Stone ovens in our
Products section.
|
 |
 |
 |
|
 |
Allow 8” min. opening between any
façade and the front edge of the hood to allow for filter
removal. Install hood in accordance with the instructions on the
hood data plate.
|
 |
3. Exhaust from Wood Stone
dual-temperature, gas-fired ovens (Model numbers ending with RFG-IR and
RFG) can be vented using one of the previously mentioned methods OR can
be combined with exhaust from other equipment, assuming the common duct
meets the construction requirements listed in #1. Exhaust from solid
fuel equipment must be vented separately from non-solid fuel equipment.
If the Wood Stone oven is installed using
the direct connect method, and is going to be tied into a common duct
that is connected to any hoods; the system must be engineered so the
duct pressure at the oven flue collar is -0.1”W.C. (-0.14”W.C. for solid
fuel applications.) Failure to properly engineer the venting system will
severely compromise oven performance and reliability. Tying a direct
connected Wood Stone oven into a common duct may not be a feasible
solution for many installations. In these cases the oven must either be
vented separately, or vented using a Type 1 hood. Consult with a
qualified mechanical engineer and submit your plans to your local code
officials for approval before proceeding.
IMPORTANT SAFETY CONSIDERATIONS
Solid-fuel exhaust contains creosote and
other substances that accumulate in ducting, creating a risk of fire.
The rate of accumulation will vary with respect to flue gas temperature,
wood type and moisture content. Frequent, regularly scheduled, thorough
flue cleaning is the best way to minimize the risk of flue fires.
It is never appropriate to use B
"vent" in any part of an exhaust system connected to a Wood Stone oven.
All ducting material must be manufactured to the specifications of a
grease duct. Due to the possibility of sparks entering the duct,
exhaust systems serving solid-fuel equipment SHOULD NOT
be combined with exhaust systems serving other (non-solid-fuel)
equipment.
VERY IMPORTANT!
WOOD STONE RECOMMENDS THAT YOU SUBMIT YOUR
VENTING PLANS TO LOCAL CODE AUTHORITIES
BEFORE
PROCEEDING WITH INSTALLATION.